登陆成功…?/p>
供应商信?/p>
产品概述9/span>
SDI是依据取样水?span lang="EN-US">0.207MPA压力下通过0.45μm的微孔滤膜过滤在一定时间内产生的流量衰减推算而来的、span lang="EN-US">SDI值是表征预处理的出水中胶体和颗粒含量的有效方法之一,是确保反渗透等膜分离过程有效运行的重要指标、/span>
SDI测试膜片/SDI滤膜/SDI测试专用膜规格:Φ47
精度9span lang="EN-US">0.45μm
包装9span lang="EN-US">100牆span lang="EN-US">/盒(兰span lang="EN-US">4小盒?span lang="EN-US">25牆span lang="EN-US">/小盒(span lang="EN-US">
SDI膜片主要用于反渗透系统中SDI(污染指数)值的测定,严格按照美囼span lang="EN-US">ATME标准生产,通过测试一定压力下通过的微孔滤膜过滤流量衰减情况来计算SDI值。产品索引:SDI膜片,密理博SDI膜片+span lang="EN-US">Millipore SDI膜片,密理博Millipore SDI?span lang="EN-US">SDi膜片,密理博SDI测定膜片+/span>SDI污染指数测试膜片+span lang="EN-US">SDI测定仪,SDi检测仪+/span>MilliporeSDI?/span>专用膜片、span lang="EN-US">
SDI测定是基于阻塞系数(PI+span lang="EN-US">%)的测定。测定是?/span>&
PI='span lang="EN-US">1,span lang="EN-US">Ti/Tf)Öspan lang="EN-US">100
SDI=PI/15式中15?span lang="EN-US">15分钟。当水中的污染物质较高时,滤水量可取100ml?span lang="EN-US">200ml?span lang="EN-US">300ml等,间隔时间可改丹span lang="EN-US">10分钟?span lang="EN-US">5分钟等、span lang="EN-US">
测定SDI的步骤:
尅span lang="EN-US">SDI测定仪连接到取样点上(此时在测定仪内不装滤膜)、span lang="EN-US">
打开测定仪上的阀门,对系统进行彻底冲洗数分钟、span lang="EN-US">
关闭测定仪上的阀门,然后用钝头的镊子抉st1:chmetcnv w:st="on" unitname="m" sourcevalue=".45" hasspace="True" negative="False" numbertype="1" tcsc="0">0.45?m的滤膜放入滤膜夹具内、span lang="EN-US">
确认O形圈完好,将O形圈准确放在滤膜上,随后将上半个滤膜夹具盖好,并用螺栓固定、span lang="EN-US">
稍开阀门,在水流动的情况下,慢慢拧杽span lang="EN-US">1-2个蝶形螺栓以排除滤膜处的空气、span lang="EN-US">
确信空气已全部排尽且保持水流连续的基础上,重新拧紧蝶形螺栓、span lang="EN-US">
完全打开阀门并调整压力调节器,直至压力保持?span lang="EN-US">30psi为止。(如果整定值达不到30 psi时,则可在现有压力下试验,但不能低于15 psi。)
用合适的容器来收集水样,在水样刚进入容器时即用秒表开始记录,收取500ml水样所需的时间为TO(秒)。水样继续流?span lang="EN-US">15分钟后,再次用容器收集水栶span lang="EN-US">500ml并记录收集水样所花的时间,记佛span lang="EN-US">T15(秒)、span lang="EN-US">
关闭取样进水球阀,松开微孔膜过滤容器的蝶形螺栓,将滤膜取出保存(作为进行物理化学试验的样品)、span lang="EN-US">
擦干微孔过滤器及微孔滤膜支撑孔板、span lang="EN-US">
测定结果计算9/span>
a.当试验过程中压力丹span lang="EN-US">30 psi时,按照下式计算SDI值:SDI='span lang="EN-US">1,span lang="EN-US">Ti/Tf)Öspan lang="EN-US">100/15
b.当测量过程中压力打不?span lang="EN-US">30 psi旵span lang="EN-US">,可改用现有压力,但测得的SDI值必须换算到30 psi时的SDI值,方法如下9span lang="EN-US">
%Pp='span lang="EN-US">1,span lang="EN-US">Ti/T15)Öspan lang="EN-US">100'span lang="EN-US">%Pp为非标准压力30 psi时的阻塞指数(span lang="EN-US">SDI=%P30/15
注意
A.每次试验过程中压力要稳定,压力波动不得超过°span lang="EN-US">5%,否则试验作废、span lang="EN-US">
B.选定收集水样量应丹span lang="EN-US">500ml(或其他确定的水量值);两次收集水样的时间间隔丹span lang="EN-US">15分钟、span lang="EN-US">
C.归span lang="EN-US">T15?span lang="EN-US">Ti皃span lang="EN-US">4倍时+span lang="EN-US">SDI值是5;如果水样完全将膜片堵住时,SDI15值为6.7、span lang="EN-US">
以上是关亍b>SDI测试膜片的详细介绍,产品田b>南京博滤工业设备有限公司为您提供,如果您寸b>南京博滤工业设备有限公司产品信息感兴趣可?a class="checkContactWay" href="">联系供应啅/a>,您也可以查看更多相关的产品?/p>
许晟先生(销售部 经理)
13915988256
公司电话?25-52265538
公司传真?25-52268258
联系我时务必告知是在114批发网上看到的!
免责声明9/span>以上信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责?14批发网对此不承担任何责任
友情提醒9/span>为规避购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量